The Apollo 500+ features a comprehensive range of electrical safety tests with user configurable test sequences and checklists for PAT, PPM and PPE. It has storage for up to 10,000 test records and is compatible with our Seaward PATGuard 3 software for record keeping and reporting.
Now updated to fully comply with the 5th Edition Code of Practice.
Free 5th Edition Firmware
The Apollo 500+ is a great value PAT tester with a comprehensive range of tests, advanced data transfer and storage features. It also has a built-in electrical risk assessment tool to suggest inspection and test frequencies.
Designed to enable simple, professional and fast PAT testing, with remote data transfer, upload/download and a large memory to store up to 10,000 test records. Great for high volume testing, or if you are retesting a large number of appliances on a regular basis.
For faster and more efficient retesting, the Apollo 500+ can be used with Seaward’s PATGuard 3 software to upload equipment details from your existing database, saving time on data entry in the field.
Printing Seaward QR barcodes, using the Test n Tag Elite 2 printer, enables you to store equipment details on the label, making retesting faster even if data has not been uploaded to the tester.
This PAT testing kit includes:
Part number: 380A9899
The Elite Kit is also available with PATGuard 3 software. Part number: 380A9900
This PAT testing kit includes:
Part number: 380A9896
The Elite Kit is also available with PATGuard 3 software. Part number: 380A9897
General Features | Apollo 400+ | Apollo 500+ | Apollo 600+ |
5th Edition Compliant | ![]() |
![]() |
![]() |
Battery & mains powered | ![]() |
![]() |
![]() |
Colour screen & QWERTY keypad | ![]() |
![]() |
![]() |
Large internal memory | Up to 2,000 records | Up to 10,000 records | Up to 50,000 records & 2,000 visual inspection images |
Bluetooth scanner & printer compatible | ![]() |
![]() |
![]() |
Password controlled user accounts | ![]() |
![]() |
|
Set up multiple user accounts with varying levels of privileges | ![]() |
![]() |
|
Clone facility to set up multiple testers | ![]() |
![]() |
|
Checkbox supplied as standard | ![]() |
![]() |
|
Test Inspection Features | Apollo 400+ | Apollo 500+ | Apollo 600+ |
Auto-increment asset ID | ![]() |
![]() |
|
PAT Setup option to allow for custom menus | ![]() |
![]() |
|
Enter asset description after test using keypad or barcode scanner | ![]() |
![]() |
![]() |
Comprehensive electrical safety test features | ![]() |
![]() |
![]() |
Point to point measurement (Rpe & IR) | Optional accessory required | ![]() |
![]() |
User configurable electrical test/visual inspection sequences | 25 | 100 | 100 |
User set sites & locations | 50 | 100 | 100 |
Risk based retest period calculator | ![]() |
![]() |
|
User definable comments lines against test records | 4 | 4 | |
Configurable checklists for any workplace test or inspection (user tests) | ![]() |
![]() |
|
On-board camera | ![]() |
||
Universal risk assessment | ![]() |
||
Health & safety certificates | ![]() |
||
Data transfer features | Apollo 400+ | Apollo 500+ | Apollo 600+ |
1D & 2D scanner connectivity | Reads 1D data only | ![]() |
![]() |
Read 2D barcode labels with 2D scanner | ![]() |
![]() |
|
RFID reader connectivity | ![]() |
||
Print pass & fail labels with 1D barcode | ![]() |
![]() |
![]() |
Print pass & fail labels with 2D barcode | ![]() |
![]() |
|
Add your company logo to labels (large 1D labels only) | ![]() |
![]() |
|
Select various label formats to print | 6 | 6 | 6 |
Download to PC via USB cable | ![]() |
![]() |
![]() |
Data transfer via USB flash drive | ![]() |
||
Filter results to be downloaded | ![]() |
![]() |
![]() |
Upload previous results to tester for retest | ![]() |
![]() |
If you're already an Apollo Series user you can update your firmware to the latest version 4.1.7 (5th Edition) where you'll be able to benefit from the new selection of test sequences created in response to the newly release 5th Edition IET code of practice. Installing this firmware will also allow your existing 4th Ed. Apollo to test up to 5mA for protective conductor current and 3.5mA* touch current.
*5mA for new 5th edition products.
Investment in advanced Seaward PAT (portable appliance testing) kits is helping London Underground comply with important electrical safety requirements. London Underground, one th...
Oxfordshire City Council’s property maintenance and support services company is ensuring it meets its portable appliance testing (PAT) responsibilities with electrical safety tes...
Investment in the latest appliance testing technology is helping a specialist electrical contracting business to introduce dedicated company-wide testing protocols and standards as...
When the AV and lighting specialist White Light needed testing equipment for some of its more complex projects, they knew Seaward had the perfect solution. Starting life as a...
The powerful data handling capabilities of modern test technology is helping a local PAT Superhero to deliver effective workplace testing to give employers confidence that their ...
An integrated electrical safety testing package from Seaward is helping social housing organisation Gentoo Group meet its portable appliance testing (PAT) requirements. North Eas...
Advanced electrical testing technology is helping the UK’s leading college for those with sight loss maintain the highest standards of safety. The Royal National College for the...
Seaward’s latest generation portable appliance testers combine electrical safety testing with a comprehensive data logging capability for all workplace health and safety equipme...
Earth Continuity (Rpe) | |
---|---|
Test Current | +/- 200mA DC |
Measurement Range | 0.05Ω to 19.99Ω |
Pass Value | User defined |
IEC Lead Test | |
---|---|
Test Voltage | 5VAC nominal |
Test | Live / Neutral Checks for o/c, s/c and crossed polarity |
Touch Current | |
---|---|
Test Voltage | Supply voltage, maximum load current 16A |
Measurement Range | 0.10mA to 5mA |
Pass Value | User defined |
Substitute (Alternative) Leakage Current | |
---|---|
Test Voltages | >25VAC <50VAC |
Measurement Range | 0.20mA to 19.99mA |
Pass Value | User defined |
Power Socket Test | |
---|---|
Voltage Range | 207V – 253VAC |
Indicates configuration of voltage potential:- | Line potential phase to earth |
Line potential phase to neutral | Line potential neutral to earth |
Insulation Resistance (IR) | |
---|---|
Test Voltage | 500V / 250VDC @ 1mA nominal |
Measurement Range | 0.10MΩ to 19.99MΩ |
Pass Value | User defined |
Protective Conductor Current/Load | |
---|---|
Test Voltage | Supply voltage, maximum load current 16A |
Measurement Range | 0.25mA to 19.99mA |
Pass Value | User defined |
Load Power/Current | |
---|---|
Test Voltage | 230V +10%, -15%, maximum load current 16A |
Test Duration | Programmable up to a maximum of 240s |
Measurement Range | 0.50A to 16.0A |
RCD Test | |
---|---|
Test Voltage | 230V +10%, -15% |
Test Current | 30mA / 150mA rms sinusoidal |
Display Range | 0ms to 2000ms |
Test Method | Internal isolation to avoid tripping distribution board RCD |
General | |
---|---|
Memory size | up to 10,000 records |
Weight | 1.5kg |
Dimensions | 230mm x 150mm x 100mm |
Power Source | Mains or rechargeable battery pack |
Register your Apollo 500+ today to activate your warranty and to stay up to date with the latest product updates, news and support information.