The SS:200LR Wireless Irradiance Meter is the ideal tool for solar photovoltaic and solar thermal professionals, designed to deliver precise site survey measurements and seamless wireless integration with the Seaward PV:1525 tester.
Together, they provide real-time irradiance, temperature, and orientation data for accurate on-site testing and full IEC 62446 report generation.
The SS:200LR Wireless Irradiance Meter is a robust handheld instrument designed for solar photovoltaic and solar thermal professionals to carry out comprehensive on-site surveys. In addition to measuring solar irradiance, it features an integrated inclinometer for roof pitch, a compass for orientation, and thermometers for both ambient air and module temperature. These built-in functions make the SS:200LR an indispensable all-in-one survey tool, helping to ensure optimal installation conditions for every solar system.
The SS:200LR introduces long-range wireless connectivity with the Seaward PV:1525 Solar PV Tester, enabling real-time transmission of irradiance, ambient, and module temperature data during electrical testing as required by IEC 62446 standards. This combined data set can then be imported directly into SolarCert software for seamless report generation and system certification.
A built-in data logging function with USB interface allows irradiance and temperature values to be recorded at user-defined intervals over hours or days. This feature is ideal for evaluating site conditions or assessing system performance over time, with results easily downloaded to a PC for further analysis.
Using a photovoltaic reference cell for measurement, the SS:200LR provides highly accurate and repeatable readings in W/m² or BTU/hr-ft², making it suitable for both PV and solar thermal applications. Its durable design, advanced connectivity, and enhanced functionality make it a key component of Seaward’s next-generation solar testing platform.
| SS 100 | SS 200R | SS:200LR | |
|---|---|---|---|
| IEC 62446 compliant | |||
| Irradiance measurement (using solar reference cell) | |||
| Compass function | |||
| Roof pitch measurement | |||
| Ambient temperature | |||
| PV module temperature | |||
| Datalogging function | |||
| Wireless connectivity (Range) | 30 m Line of sight | 150 m Line of sight | |
| Max irradiance measurement | 1250 W/m² | 1500 W/m² | |
| Compatible instrument | PV150+ / PV200 / Solar Utility Pro | PV:1525 |
| Irradiance Measurement | |
|---|---|
| Display range | 100 ... 1999 W/m2 / 30 ... 633 BTU/hr-ft2 |
| Measurement range | 100 ... 1500W/m2 / 30 ... 475 BTU/hr-ft2 |
| Resolution | 1 W/m2 / 1 BTU/hr-ft2 |
| Compass Bearing | |
|---|---|
| Display range | 0° ... 360° |
| Measuring range | 0° ... 360° |
| Resolution | 1° |
| Mechanical Design | |
|---|---|
| Weight | Approx. 0.25 kg / 0.6 lb (without batteries) |
| Dimensions | Approx. 14.8 cm × 8.0 cm × 3.3 cm / 5.8“ × 3.2“ × 1.3“ |
| Protective system | Housing: IP40 as per IEC 60529 (Protection against ingress of solid foreign objects: ≥ 1.0 mm / 0.039” Ø; protection against ingress of water: not protected) |
| Display | Custom LCD |
| Power Supply | |
|---|---|
| Power Source | 2 × AA Alkaline batteries |
| Battery Life | >20,000 readings |
| Auto power dow | After • 30 min of measured darkness • 15 min from switch on with no initial pairing to a PV:1525 and no button presses • 12 hours after first switch on |
| Onboard Memory | 5000 datasets |
| Electromagnetic Compatibility (EMC) | |
|---|---|
| Interference emission | IEC 61326-1, class A |
| Interference immunity | IEC 61326-1 |
| Temperature Measurement | |
|---|---|
| Display range | –30 °C ... +125 °C |
| Measuring range | –30 °C ... +125 °C |
| Resolution | 1° |
| Inclinometer | |
|---|---|
| Display range | 0° ... 90° |
| Measurement range | 0° ... 90° |
| Resolution | 1° |
| Environmental Conditions | |
|---|---|
| Environment | Dry, without moisture condensation indoor or outdoor use |
| Operating temperature | +0 °C … +40 °C / +32 °F … +104 °F |
| Storage | –25 °C … +65 °C / –13 °F … +149 °F Dry, without moisture condensation; without battery pack |
| Electrical Safety | |
|---|---|
| Pollution degree | 2 |
| Connectivity | |
|---|---|
| Sample rate | Sample rate1 ... 60 minutes (user-definable) |
| Connection to PV:1525 | Wireless (range c. 150 m – line of sight); Long-Range RF |
| Frequency band(s) | 433.375 MHz … 434.625 MHz |
| Transmit power range(s) | 4.89 dBm ERP |
| Modulation type(s) | CSS |
| Channel spacing(s) | 250 kHz |
| Radio spectrum efficiency (Art. 3.2) | ETSI EN 300 220-2 V3.2.1 |
| Antenna type and gain | FPC antenna, 2.8 dBi peak gain |