| Short Circuit Current Measurement (PV Terminals) | |
|---|---|
| Display Range | 0.00ADC - 25.00ADC |
| Measuring Range | 0.50ADC - 25.00ADC |
| Maximum Power | 37.5kW |
| Resolution | 0.01 ADC maximum |
| Accuracy | ± (1 % + 2 digits) |
| Insulation Resistance Measurement (4mm Terminals) | |
|---|---|
| Test Voltage Open Circuit | 250, 500, 1000, 1500V (as per IEC61557-2) |
| Test Current Short Circuit | < 2mA |
| Display Range | 0.05 MΩ - 999 MΩ |
| Measuring Range (EN61557-2) | 250 V / 500 V string mode: 0.05 MΩ … 200 MΩ 1 kV / 1.5 kV string mode: 0.05 MΩ … 999 MΩ 250 V point to point: 0.05 MΩ … 300 MΩ 500 V point to point: 0.05 MΩ … 500 MΩ 1 kV / 1.5 kV point to point: 0.05 MΩ … 999 MΩ |
| Resistance resolution | 0.01 MΩ for 0.05 MΩ … 1.99 MΩ 0.1 MΩ for 2.0 MΩ … 19.9 MΩ 1 MΩ for 20 MΩ … 999 MΩ |
| Visible Warning | ≥30V AC or DC at inputs |
| Circuitry Protection | Test inhibited if ≥30V AC or DC at inputs |
| Repeat tests as per IEC61557-4 | Approx 4000 1 second tests |
| Test voltage specification | –0 % +20 % (open-circuit) |
| Test voltage at 1 mA | > 1 mA into Un × (1000 Ω/V) (as per IEC 61557-2) |
| Resistance accuracy | ±(5 % + 1 digit) for 0.05 MΩ … 0.19 MΩ ±(5 % + 3 digit) for 0.20 MΩ … 1.99 MΩ ±(5 % + 2 digit) for 2.0 MΩ … 5.0 MΩ ±(5 % + 5 digit) for 5.1 MΩ … 99 MΩ ±(10 % + 5 digit) for > 99 MΩ |
| Insulation voltage resolution | 1 V |
| Insulation voltage accuracy | ±(2 % + 2 counts) |
| Maximum system capacitance | 2 μF |
| Operating Power (PV Terminals & wireless using PV:1500 Clamp) | |
|---|---|
| Display Range | 0.00kW - 600kW |
| Measuring Range | 0.50kW - 600kW |
| Resolution | 0.01kW |
| Accuracy | ± (6 % + 2 digits) |
| Maximum Power – String Test | |
|---|---|
| String test maximum power rating | 37.5 kW* at panel efficiency ≤ 19 % 25 kW* at panel efficiency > 19 % |
| Voltage | up to 1500 VDC |
| Current | up to 25 ADC |
| Open Circuit Voltage Measurement (PV Terminals) | |
|---|---|
| Display Range | +10.0 VDC … +1500 VDC / –10.0 VDC … –440 VDC 10.0 VAC … 440 VAC |
| Measuring Range | +10.0 VDC … +1500 VDC / –10.0 VDC … –440 VDC 10.0 VAC … 440 VAC |
| Resolution | 0.1VDC maximum |
| Accuracy | for +DC: ± (0.5 % + 2 digits) for –DC and AC: ± (5 % + 2 digits) |
| Earth Continuity / Resistance Measurement (4mm Terminals) | |
|---|---|
| Test Voltage Open Circuit | >4VDC, nominal |
| Test Current into 2Ω | >200mA |
| Display Range | 0.00Ω - 199Ω |
| Measuring Range (EN 61557-4) | 0.05Ω - 199Ω |
| Resolution | 0.01Ω maximum |
| Test Leads Zero | Zero up to 10Ω |
| Visible Warning | ≥30V AC or DC at inputs |
| Circuitry Protection | Test inhibited if ≥30V AC or DC at inputs |
| Repeat tests as per IEC61557-4 | Approx 4000 1 second tests |
| Accuracy | 0.05 Ω … 0.09 Ω ± (2 % + 1 digit) 0.10 Ω … 0.19 Ω ± (2 % + 2 digits) 0.20 Ω … 1.99 Ω ± (2 % + 3 digits) 2.0 Ω … 4.9 Ω ± (2 % + 2 digits) 5.0 Ω … 199 Ω ± (2 % + 5 digits) |
| Operating Current (Wireless via PV:1500 Clamp) | |
|---|---|
| Display Range | 0.1A - 400.0A DC |
| Current Measuring Range | 0.1A 400A DC |
| Resolution | 0.1 A |
| Accuracy | ± (5 % + 2 digits) |
| General Specification | |
|---|---|
| Weight | 1kg / 2.2lb |
| Dimensions | 265 x 115 x 78 mm 10.4 x 4.6 x 3.1 in |
| Display | 3.5in Colour display with Backlight |
| Power Source | 11.55V 2930mAH LiPo Battery (rechargeable) |
| Auto Power Down | User Configurable |
| Onboard Memory | 1000 Slots |
| Display resolution | 480 × 320 pixels |
| Display FOV | 70° left to right 60° top to bottom |
| IV Curve (PV:1525-IV only) | |
|---|---|
| Minimum number of test points | 20 |
| IV curve maximum power rating | 37.5 kW* at panel efficiency ≤ 19 % 20 kW* at panel efficiency > 19 % |
| Voltage | up to 1500 VDC |
| Current | up to 25 ADC |